The Function Of Hospital Baby Equipment Infant Care Incubator BIN3000BD:
The infant incubator has a temperature control system and a humidity control system. The temperature control system includes two control working modes: air mode and skin temperature mode. Control of temperature heating output under air mode: The air temperature detected by the temperature sensor in the infant incubator is from the thermal output of the control heater; the control of the temperature heating output under the skin temperature mode: The skin temperature detected according to the temperature sensor comes from the heat output of the control heater. Humidity control system: The humidity detected by the humidity sensor in the infant incubator comes from the humidifier in the water tank.
The machine and seats are used as auxiliary parts to support the cultivation box and other components, and provide the corresponding work height according to the needs. Radiation light box (jaundice treatment device) has the function of treating bilirubin in the treatment of infants. The weighing system has the function of monitoring the weight change of the baby at any time.
Product feature:
Air temp.and skin temp.servo-controlled by computer
Humidity servo-control by computer
>37ºC temperature setting
Various self-checkalarms
Free-step mattress tilting adjustmentRemovable humidity trough, easy to cleanWith the transfusion shelf and tray
Added with guardrail
RS-232 connectorPhototherapy(option)o2 controller(option)Electrical scale (option)
The Precautions Of Medical Infant Incubator:
1. If there are debris (such as blankets, animal toys, etc.) in the air circulation channel. In clinical use, it will affect the safety of patients and the performance of the infant incubator.
2. Do not put the clothes or blankets around the patient or at the ventilated mouth, which may cause the patient to overheat, thereby forming damage and burns.
3. The cultivation box needs to be moved by at least two people with a certain force. The pull handle on both sides of the infant incubator can be used as a mobile handle. Before moving, you need to pull out the power supply line of the device and all other cables.
4. To prevent damage to accidental movement, the infant incubator must be locked during the normal use.
5. In order to prevent accidental disconnection, when moving the crib, you should ensure that each wire, the infusion pipe and the ventilation pipe have sufficient length between the infant mattress, which can make the crib to move in all directions.
Infant Care Incubator BIN3000BD parameters | |
Packing size(Up) | 108*64*92cm |
Packing size(Down) | 108*64*70cm |
N.W.(Up) | 65Kg/51Kg |
N.W.(Down) | 55Kg/44Kg |
Mattress temp. uniformity | ≤0.8ºC |
Environment relative humidity | ≤80% |
Atmospheric Pressure | 500~1060hpa |