Type: | Special Animal Anesthesia Machine |
---|---|
Syringe: | Metal Syringe |
Breathing Pattern: | Auto-Control |
Animal Anesthesia Machine Control Method: | Electronic Control |
Display: | 8 " TFT, with Touch Screen. |
Inlet Pressure: | 280-600 Kpa. |
Customization: |
---|
Suppliers with verified business licenses
Hot sale Veterinary Anesthesia Ventilator with Color Touch Screen ME03 Pet Ventilator
Veterinary Anesthesia Ventilator Product Feature:
Basic description |
||
Parameter |
Description |
|
Display |
8 " TFT, with touch screen. |
|
Drive gas |
Gas type |
O2 or Air |
Inlet pressure |
280-600 kPa. |
|
Max flow |
≤ 120 L / min. |
|
Operating Mode |
VCV,PCV,SIMV-VC,SIMV-PC,PSV,Manual/SPONT. Optional: SIMV-PRVC, PRVC |
|
Waveform |
Waveform: Pressure,Flow-rate,Volume,CO2(optional),Pleth(optional) Loop:PV loop, PF loop,FV loop |
|
Safety Pressure |
System pressure does not exceed 10 KPa. |
|
Battery Type |
Li-ion,work time more than 3 hours |
monitored parameters |
|
Parameter |
Description |
Inspiratory tidal volume |
Range: 0 ~ 2500 mL; Resolution: 1 mL. Error of ± 20mL or actual value ± 15%, which ever is greater |
Expiratory tidal volume |
Range: 0 ~ 2500 mL; Resolution: 1 mL. Error of ± 20mL or actual value ± 15%, which ever is greater |
Minute ventilation |
Range: 0 ~ 60 L / min; Resolution: 0.1 L / min. Error of ± 1L/min or actual value ± 15%, which ever is greater |
Spontaneous minute ventilation |
Range: 0 ~ 60 L / min; Resolution: 0.1 L / min. Error of ± 1L/min or actual value ± 15%, which ever is greater |
Respiratory rate |
Range: 0 ~ 100 bpm; Resolution: 1 bpm. Error of ± 2 beats / min or actual value ± 10%, which ever is greater |
Spontaneous breathing frequency |
Range: 0 ~ 100 bpm; Resolution: 1 bpm. Error of ± 2 beats / min or actual value ± 10%, which ever is greater |
Respiratory ratio |
Range: 30:1 to 1:150; resolution: 0.1. Error of ± 20%, |
Peak airway pressure |
Range: 0 ~ 100 cmH2O; Resolution: 1 cmH2O. Error of ± (2% + 4% of full scale actual reading) |
Mean airway pressure |
Range: 0 ~ 100 cmH2O; Resolution: 1 cmH2O. Error of ± (2% + 4% of full scale actual reading) |
PEEP |
Range: 0 ~ 100 cmH2O; Resolution: 1 cmH2O. Error of ± (2% + 4% of full scale actual reading) |
Inspiratory plateau pressure |
Range: 0 ~ 100 cmH2O; Resolution: 1 cmH2O. Error of ± (2% + 4% of full scale actual reading) |
FiO2(optional) |
Range: 15 to 100%; Resolution: 1%. Error is ± (2.5% +2.5% of full scale actual reading) |
Compliance |
Range: 0 ~ 300 mL/cmH2O; resolution: 1 mL/cmH2O. Error of ± 20% or ± 5 mL/cmH2O, which ever is greater |
Airway resistance |
Range: 0 ~ 600 cmH2O / (L / S); Resolution: 1 cmH2O / (L / S). Error of ± 20% or ± 5 cmH2O, which ever is greater |
EtCO2 (optional) |
Range: 0 ~ 100 mmHg; Resolution: 1 mmHg. Error is ± (0.43% of the volume percentage + 8% of the gas concentration) is equivalent to the range of optional units to monitor KPa and mmHg. |
Inhalation of carbon dioxide (optional) |
Range: 0 ~ 100mmHg; Resolution: 1 mmHg. Error is ± (0.43% of the volume percentage + 8% of the gas concentration) is equivalent to the range of optional units to monitor KPa and mmHg. |
MAC values(optional) |
Range: 0 to 10; resolution: 0.01 |